LuMark

 

Lutetium-177 (177Lu) Research Radionuclide*

 

 

Radionuclide                                                    177Lu, reactor produced from a 176Lu target

Calibration day                                                 Weekly on Fridays; other days on request

Calibration time                                                12.00 hr CET at the end of production

Shipment day                                                   Weekly as from Wednesdays or as requested

Order deadline                                                 minimum two weeks prior to shipment

 

Physical Half Life                                              6.71 days                                                        

Radiation                                                          b- (Emax in KeV)

175 (12,3%)

380 (  9   %)

497 (78,7%)

 

g  (E in KeV):

208 ( 11  %)

113 (   6  %)

 

Radionuclide purity                                           <1% 175Lu, 175Lum, 176Lu

Radiochemical purity                                         >99%

Specific activity                                                 >740 GBq/mg at calibration time

Activity concentration                                       37 MBq - 111GBq/ml at calibration time

 

Chemical form                                                   Lu chloride (LuCl3) in 0.05 M HCl

pH                                                                   1.3

 

Storage                                                             Room temperature (15-20 0C)

 

 

 

 

* For laboratory use only. At the time of printing these specifications are believed to be accurate. Regulatory requirements may change and differ per country and this information is not tailored to individual needs. For specific applications a radiation safety officer should be consulted.

 

 

 

 

 